I regularly receive two questions from those interested in my PML-TX01. Both are about the Marshall JMP-1 input voltage selection:

  1. Is the PML-TX01 replacement transformer for the Marshall JMP-1, 230V or 115V?
  2. Are the voltage selector components diodes, ferrite beads or just fancy wire links?
Marshall JMP-1 voltage selection with PML-TX01
Here are the link locations to select the voltage rating of the primary windings for the transformer in a Marshall JMP-1. The example shown is set to 230V.

The answer to the first question is, just like the original TXMA-00014, my PML-TX01 has two separate primary windings, each rated at 115V. So…

  • EUOPEAN / UK VOLTAGE SELECTION. Wired in series, the primary becomes a single 230V winding which is suitable for 220V (Europe) and 240V (UK, Australia). To wire in series, connect ONLY LK2.
  • USA / CANADA / JAPAN VOLTAGE SELECTION. Wired in parallel, the primary becomes a single 115V winding suitable for 120V (USA and Canada), 100V (Japan). To wire in parallel, connect LK1 and LK3.

It's quite easy to implement 240V to 120V conversion, or 120V to 240V, for example. Those eighties style wire links can make things look complicated but the original links were JUST WIRE LINKS and nothing else, so you can use wire.

JMP-1 Input Voltage Selection Schematic
Looking from the pin side of the transformer, here are the voltage selection links and secondary transformer voltages. Apart from the higher quality material used for the laminates, the PML-TX01 is a direct drop-in replacement for the original Dagnall TXMA-00014.

It's important that the input voltage selection is chosen properly so below things are drawn that may be more representative of what you might actual see in your JMP-1.

JMP-1 Input Voltage Layout
Here's a diagram which resembles the actual physical layout of the power feed and primary voltage selection in the Marshall JMP-1.

SIDE NOTE

One might ask why the two individual primary windings are put in parallel for 115V. Why not just use one winding?

Well, a system uses a certain amount of power. Power is the product of voltage and current: P = V x I.

You can probably see now that if you half the voltage, you'll need twice the current to deliver the same amount of power. Placing the two primaries in parallel does just that, it doubles the current going into the system. 🙂

Check out my PML-TX01 low heat and low noise replacement transformer for the Marshall JMP-1 here.

And lastly...

! ! ! DON'T FORGET TO CHECK THE FUSE RATING ! ! !

So as I've just intermated, the power requirement of a machine is the same whatever the supply voltage. Since power = current x voltage, if you're halving the voltage, you'll be doubling the current.

Marshall JMP-1 fuse
Don't forget to select the correct fuse rating for your region.

If running at 230V, the JMP-1 fuse should be 80mA (230V x 0.08A = 18.4W).
If running at 115V, the JMP-1 fuse should be 160mA (115V x 0.16A = 18.4W).

'T' stands for 'time delay' so use a time delay fuse.